Tetrachloroethylene CAS#127-18-4

Tetrachloroethylene CAS#127-18-4

High-Performance Industrial Solvent:Tetrachloroethylene is widely used as an effective industrial solvent and as a cooling and insulating liquid in electrical transformers, delivering reliable performance in demanding applications.


Safe Non-Flammable Properties:This colorless, volatile liquid is nonflammable and features a mild ether-like odor, providing improved safety and ease of handling compared with many organic solvents.


Excellent Thermal & Chemical Stability:With strong resistance to heat and chemical reactions, tetrachloroethylene maintains stable performance in high-temperature and electrically sensitive environments.


Advanced Industrial Production Technology:Manufactured mainly through high-temperature chlorinolysis of light hydrocarbons, tetrachloroethylene offers consistent quality suitable for large-scale industrial use.


Phone :+86 15966245583
WhatsApp :+86 15966245583
Email :admin@kaiviochem.com
Get a quote
product description

Product Description of Tetrachloroethylene CAS#127-18-4

Tetrachloroethylene is a chlorinated hydrocarbon with the molecular formula Cl₂C=CCl₂, widely used as an industrial solvent and as a cooling and insulating liquid in electrical transformers. It appears as a colorless, volatile liquid with a mild ether-like odor and is nonflammable, providing enhanced safety in industrial environments.

Most tetrachloroethylene is produced through high-temperature chlorinolysis of light hydrocarbons, ensuring stable supply and consistent product quality for large-scale industrial applications.


Product Application of Tetrachloroethylene CAS#127-18-4

Tetrachloroethylene (PCE) is also known as perchloroethylene, tetrachloroethene, and 1,1,2,2- tetrachloroethene and is also commonly abbreviated to PER or PERC. Tetrachloroethylene is a volatile, chlorinated organic hydrocarbon that is widely used as a solvent in the dry-cleaning and textile-processing industries and as an agent for degreasing metal parts. It is an environmental contaminant that has been detected in the air, groundwater, surface waters, and soil (NRC, 2010).


Parameters


Melting point-22 °C (lit.)
Boiling point121 °C (lit.)
density1.623 g/mL at 25 °C (lit.)
vapor density5.83 (vs air)
vapor pressure13 mm Hg ( 20 °C)
refractive indexn20/D 1.505(lit.)
Fp120-121°C
storage temp.Store at +2°C to +25°C.
solubilitywater: soluble0.15g/L at 25°C
formLiquid
colorAPHA: ≤10
Odorchloroform-like odor
Odor Threshold0.77ppm
Water SolubilityMiscible with alcohol, ether, chloroform, benzene and hexane. Slightly miscible with water.
FreezingPoint-22.0℃
λmaxλ: 290 nm Amax: 1.00
λ: 295 nm Amax: 0.30
λ: 300 nm Amax: ≤0.20
λ: 305 nm Amax: 0.10
λ: 350 nm Amax: 0.05
λ: 400 nm Amax: 0.03
Merck149,190
BRN1361721
Henry's Law Constant4.97 at 1.8 °C, 15.5 at 21.6 °C, 34.2 at 40.0 °C, 47.0 at 50 °C, 68.9 at 60 °C, 117.0 at 70 °C (EPICS-GC, Shimotori and Arnold, 2003)
Dielectric constant2.5(21℃)
Exposure limitsTLV-TWA 50 ppm (~325 mg/m3) (ACGIH), 100 ppm (MSHA and OSHA); TLV-STEL 200 ppm (ACGIH); carcinogenicity: Animal Limited Evidence.
Stability:Stable. Incompatible with strong oxidizing agents, alkali metals, aluminium, strong bases.
LogP2.53 at 20℃
CAS DataBase Reference127-18-4(CAS DataBase Reference)
IARC2A (Vol. Sup 7, 63, 106) 2014
NIST Chemistry ReferenceTetrachloroethylene(127-18-4)
EPA Substance Registry SystemTetrachloroethylene (127-18-4)
ECETOC JACC REPORTTetrachloroethylene (127-18-4)


Safety Information


Hazard CodesXn,N,T,F
Risk Statements40-51/53-23/25-11-39/23/24/25-23/24/25
Safety Statements23-36/37-61-45-24-16-7
RIDADRUN 1897 6.1/PG 3
WGK Germany3
RTECSKX3850000
Autoignition Temperature260℃
TSCAYes
HazardClass6.1
PackingGroupIII
HS Code29032300
Hazardous Substances Data127-18-4(Hazardous Substances Data)
ToxicityLD50 orally in mice: 8.85 g/kg (Dybing); LC for mice in air: 5925 ppm (Lazarew)
IDLA150 ppm


Factory Showcase
拼图_美图设计室-(1)
Quality Control Lab
实验室
Shipping And Transportation

Delivery Time

Inventory 2-3 working days New manufacturing 7-10 working days

Mode of Transportation
1. By Air, fast but expensive.
2. By Sea, usual and economy.
3. By Train, suit for middle Asia countries.
4. By Express, suit for small package.
We only provide highest quality goods available, accompanied by after support!

拼图_美图设计室
FAQ

1. Why Supply Chain Transparency Matters in Global Chemical Procurement
Chemical buyers evaluate more than price and delivery time. Clear specifications, matching batch documents, consistent packaging information, and traceable logistics all affect customs clearance, warehouse inspection, and production use.
When selecting a supplier, buyers should review how the company confirms specifications, manages documents, handles changes, and responds to problems. Transparent processes help reduce order risks and improve long-term procurement reliability.


2. Seven Essential Details for a Chemical Product Inquiry
A product name alone is often insufficient for an accurate quotation. Buyers should provide the product name and CAS number, key specifications or purity, final application, required quantity, packaging requirements, destination, and expected delivery time or preferred Incoterms.
If COA, SDS, TDS, special labels, certifications, or registration documents are required, these details should also be included in the initial inquiry. Complete information helps suppliers confirm product, logistics, and documentation conditions more efficiently.


3. What Are the Differences Between COA, SDS, and TDS?
A COA is a batch-specific Certificate of Analysis showing test items, required ranges, and actual results. It is mainly used for quality verification and incoming inspection.
An SDS provides safety, handling, storage, emergency, and transportation information. A TDS describes typical product properties, technical parameters, and application guidance. Buyers should confirm the required document version, language, and applicable standards before placing an order.


4. Key Conditions to Confirm Before International Chemical Transportation
Before shipment, confirm the product identity, physical form, transport classification, and applicable regulations. An SDS is an important reference, but the final shipping arrangement must also meet regulatory and carrier requirements.
Packaging, sealing, moisture protection, palletizing, labels, ports, documents, Incoterms, and transport schedules should be clearly confirmed. Early verification helps prevent delays caused by carrier restrictions or incomplete documentation.


5. How to Evaluate Chemical Product Sample Test Results
Sample evaluation should consider both product compliance and application performance. Laboratory results do not always guarantee the same performance in every formulation or production process.
Before testing, record the sample batch, COA, storage condition, and sampling method. During application tests, keep consistent records of formulation, dosage, process conditions, and results. After approval, reconfirm the formal order specifications, inspection method, packaging, and batch documents.

Contact Us
Submit Sourcing Inquiry & Request Sample
Recommendation