Glyphosate CAS#1071-83-6

Glyphosate CAS#1071-83-6

Broad-Spectrum Weed Control:Effectively controls annual, biennial, perennial, deep-rooted, sedge, and broadleaf weeds with non-selective post-emergent action.


Wide Application Range:Suitable for rubber plantations, forestry, orchards, tea gardens, rice and wheat fields, and crop rotation land, supporting diverse agricultural systems.


Flexible Dosage for Different Weeds:Precise application rates tailored to weed sensitivity ensure efficient control and optimal performance across multiple weed species.


Short Residue & Proven Safety Profile:Features a short residual life and is recognized by the U.S. EPA as relatively low in toxicity, supporting safe and sustainable weed management.



Phone :+86 15966245583
WhatsApp :+86 15966245583
Email :admin@kaiviochem.com
Get a quote
product description

Products Description of Glyphosate CAS#1071-83-6

Glyphosate, originally used for rubber plantation weed control (enabling earlier tapping and higher yields), is now widely applied across agriculture and forestry. Application rates range 6–30 g/100 m² based on weed type, requiring uniform foliar spraying. A non-selective post-emergent herbicide with short residual activity, it is one of the world's most widely used weed control agents and classified as relatively low-toxic by the U.S. EPA.


Product Applications of Glyphosate CAS#1071-83-6

Glyphosate, the active ingredient in many commercial herbicides, is a broad-spectrum systemic herbicide targeting weeds, grasses (Poaceae) and woody plants.


Parameters


Melting point230 °C (dec.) (lit.)
Boiling point465.8±55.0 °C(Predicted)
density1.74
Fp230°C
storage temp.APPROX 4°C
solubilityDMSO: slightly soluble; PBS (pH 7.2): slightly soluble
formsolid
pka1.22±0.10(Predicted)
colorWhite to off-white
Odorodorless
Water Solubility1.2 g/100 mL
Decomposition230 ºC
Merck134,525
BRN2045054
Stability:Stable. Incompatible with metals, strong oxidizing agents, strong bases. May be light sensitive.
InChIKeyXDDAORKBJWWYJS-UHFFFAOYSA-N
LogP-2.360 (est)
CAS DataBase Reference1071-83-6(CAS DataBase Reference)
IARC2A (Vol. 112) 2017
EPA Substance Registry SystemGlyphosate (1071-83-6)


Safety Information


Hazard CodesXi,N,Xn
Risk Statements41-51/53-62-37/38-36/37/38-36-22
Safety Statements26-39-61-2-37-36
RIDADRUN 3077 9/PG 3
WGK Germany2
RTECSMC1075000
HS Code29319090
Hazardous Substances Data1071-83-6(Hazardous Substances Data)
ToxicityLD50 in rats, mice (mg/kg): 4873, 1568 orally (Bababunmi)


Factory Showcase
拼图_美图设计室-(1)
Quality Control Lab
实验室
Shipping And Transportation

Delivery Time

Inventory 2-3 working days New manufacturing 7-10 working days

Mode of Transportation
1. By Air, fast but expensive.
2. By Sea, usual and economy.
3. By Train, suit for middle Asia countries.
4. By Express, suit for small package.
We only provide highest quality goods available, accompanied by after support!

拼图_美图设计室
FAQ

1. Why Supply Chain Transparency Matters in Global Chemical Procurement
Chemical buyers evaluate more than price and delivery time. Clear specifications, matching batch documents, consistent packaging information, and traceable logistics all affect customs clearance, warehouse inspection, and production use.
When selecting a supplier, buyers should review how the company confirms specifications, manages documents, handles changes, and responds to problems. Transparent processes help reduce order risks and improve long-term procurement reliability.


2. Seven Essential Details for a Chemical Product Inquiry
A product name alone is often insufficient for an accurate quotation. Buyers should provide the product name and CAS number, key specifications or purity, final application, required quantity, packaging requirements, destination, and expected delivery time or preferred Incoterms.
If COA, SDS, TDS, special labels, certifications, or registration documents are required, these details should also be included in the initial inquiry. Complete information helps suppliers confirm product, logistics, and documentation conditions more efficiently.


3. What Are the Differences Between COA, SDS, and TDS?
A COA is a batch-specific Certificate of Analysis showing test items, required ranges, and actual results. It is mainly used for quality verification and incoming inspection.
An SDS provides safety, handling, storage, emergency, and transportation information. A TDS describes typical product properties, technical parameters, and application guidance. Buyers should confirm the required document version, language, and applicable standards before placing an order.


4. Key Conditions to Confirm Before International Chemical Transportation
Before shipment, confirm the product identity, physical form, transport classification, and applicable regulations. An SDS is an important reference, but the final shipping arrangement must also meet regulatory and carrier requirements.
Packaging, sealing, moisture protection, palletizing, labels, ports, documents, Incoterms, and transport schedules should be clearly confirmed. Early verification helps prevent delays caused by carrier restrictions or incomplete documentation.


5. How to Evaluate Chemical Product Sample Test Results
Sample evaluation should consider both product compliance and application performance. Laboratory results do not always guarantee the same performance in every formulation or production process.
Before testing, record the sample batch, COA, storage condition, and sampling method. During application tests, keep consistent records of formulation, dosage, process conditions, and results. After approval, reconfirm the formal order specifications, inspection method, packaging, and batch documents.

Contact Us
Submit Sourcing Inquiry & Request Sample
Recommendation